High Output (HO) germicidal lamps yield 1/3 to 2/3 more UV
output than standard lamps of the same length.
Ballasting is available in 120v and 220v. Custom
designed lengths can also be supplied.
The unique single-ended design is suited for test
tube-shaped quartz sleeve application. The end of the
lamp with the pins is positioned at the open end of the
sleeve at the top.
This reduces electrical problems associated with
condensation at the bottom of vertical units. Electrical
continuity is accomplished through the use of two
external Teflon coated wires. Longer lengths employ
spacing rings. The 4-pin single ended design permits the
use of standard Steadfast sockets. The lamps are
supplied with ceramic bases, which are resistant to UV
and ozone. They will not burn or deteriorate, and they
eliminate quartz sleeve fogging.
Lamp Catalog Numbers
Base Face Length
Arc
Length
Watts
1
Current
mA
Voltage
50/60Hz
UV
Output at
254 nm
Inches
mm
Inches
mm
Watts
uv/cm2
05-0331
GPH436T5L
/HO/4PSE
17.2
436.0
14.2
360
48
800
70
13
120
05-0332
GPH436T5
/VH/HO/4PSE
17.2
436.0
14.2
360
48
800
70
13
120
05-0264
GHO36T5
/L/4PSE
33.2
842.4
29.7
755
87
800
125
28
260
05-0265
GHO36T5
/VH/4PSE
33.2
842.4
29.7
755
87
800
125
28
260
05-0333
GPH846T5
/L/HO/4PSE
33.3
846.0
30.2
767
90
800
127
29
265
05-0334
GPH846T5
/VH/HO/4PSE
33.3
846.0
30.2
767
90
800
127
29
265
05-0335
GPH893T5
/L/HO/4PSE
35.2
893.0
32.1
815
95
800
135
30
270
05-0336
GPH893T5
/VH/HO/4PSE
35.2
893.0
32.1
815
95
800
135
30
270
05-0337
GHO64T5
/L/4PSE
61.2
1553.6
55.9
1421
155
800
220
45
380
05-0338
GHO64T5VH
/4PSE
61.2
1553.6
55.9
1421
155
800
220
45
380
1 At line
frequencies (50 or 60Hz) the lamp wattage is not simply
the product of the lamp voltages and current. This
product of the lamp voltage and current. This product
must be multiplied by the apparent power factor
(approximately 0.8) to determine the true wattage. At
high frequency (>10Khz) the power factor is unity (one
and the wattage is obtained as the product of voltage
and current.
Atlantic Ultraviolet lamps and equipment are
manufactured in the USA.
CAUTION:
Exposure to direct or
reflected germicidal
ultraviolet rays will
cause painful eye irritation and reddening of the skin.
Personnel subject to such exposure must wear suitable
face shield, gloves and protective clothing.
*Hg - LAMP CONTAINS
MERCURY, manage in
accord with disposal
laws, see:
www.lamprecycle.org
Ster-L-Ray™
is a
trademark of the
Atlantic Ultraviolet
Corp.
Copyright 1995-2008 All rights reserved. The information and recommendations contained in this publication are
based upon data collected and are believed to be correct. However, no guarantee or warranty of any
kind, expressed or implied, is made with respect to the information contained herein. Specifications and information are subject to change without notice.